Enterasys-networks 1G58x-09 Bedienungsanleitung Seite 181

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 808
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 180
Port Configuration Command Set
Setting Flow Control and Thesholds
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 4-35
4.3.6.6 set flow agetime
Use this command to set the number of seconds flow control entries will remain active if no activity
occurs on the flow.
set flow agetime time
Syntax Description
Command Type
Switch command.
Command Mode
Read-Write.
Command Defaults
None.
Example
This example shows how to set the flow limit age time to 200 seconds:
4.3.6.7 clear flow agetime
Use this command to resets the number of seconds flow control entries will remain active to the
default value of 30 seconds.
clear flow agetime
Syntax Description
None.
Command Type
Switch command.
Command Mode
Read-Write.
time Specifies the number of seconds before flow limiting
entries will age out. Valid values are 1 - 600.
Matrix>set flow agetime 200
Seitenansicht 180