Seitenansicht 32
Compliance Standards
SecureStack C2 Installation Guide A-3
Compliance Standards
TheC2RPSPSMmeetsthesafetyandelectromagneticcompatibility(EMC)requirements
listedinTable A4:
Table A-3 C2RPS-PSM Redundant Power Supply Connector Pin Functions
Pin Number Function
1 Ground
2 No connection
3 12 Vdc Output
4 12 Vdc Output
5 12 Vdc Output
6 12 Vdc Output
7 Ground
8 Ground
9 No connection
10 No connection
11 Status 1
12 Status 2
13 Power good
14 Ground
Table A-4 Compliance Standards
Item Standard
Safety UL 60950, CSA C22.2 No. 60950, 73/23/EEC,
EN 60950, and IEC 60950
Electromagnetic Compatibility (EMC)
(Applies to RPS system with eight
modules installed and working with
eight network devices.)
47 CFR Parts 2 and 15, CSA C108.8,
89/336/EEC, EN 55022, EN 61000-3-2,
EN 61000-3-3, EN 55024; AS/NZS CISPR 22, and
VCCI V-3
Seitenansicht 32