USER’S GUIDE
476 CyberSWITCH
ERROR LCD MESSAGES
The system keeps track of all active errors and displays/records them in a cycle. When the system
detects an error, it displays the error on the first line of the LCD. (The “sindicates slot, “p”
indicates port, and “c” indicates bearer channel.) The LCD will continue to display the current
connection information on the second line.
To further investigate an error LCD message, enter the
dr
command at the console. Take the
appropriate corrective actions related to the displayed system messages.
Line vs. adapter configuration error. A line is configured for port “p” that does not exist on the
adapter in slot “s”.
Dedicated Connection failure. The Dedicated Connection on the line connected to slot “s”, port “p”,
starting at starting bearer channel “c” is down.
X.25 Permanent Virtual Circuit (PVC) failure for the indicated PVC.
Where:
access = access index
PVC = permanent virtual circuit index
The specified data link for a line is down.
(s,p) Cfg Error
Ded (s,p,c) Down
X25PVC (access, PVC) Down
DL (s,p,ces) Down
File Access Err